Browse Equivalent and Related Products
Fleet Charge SCA 50/50 Antifreeze/Coolant
Ready-to-Use SCA-Precharged Heavy-Duty Diesel Coolant
Fleet Charge SCA 50/50 Antifreeze/Coolant is a fully formulated, ethylene glycol-based heavy-duty coolant supplied precharged with Supplemental Coolant Additives, or SCAs.
The 50/50 prediluted formulation contains the proper coolant and water mixture for direct installation, so no water or additional SCA is required at initial fill. Its low-silicate, phosphate-free chemistry contains nitrite to help protect wet-sleeve cylinder liners against cavitation while also providing corrosion protection for cooling-system metals and components.
Fleet Charge is designed for heavy-duty diesel, gasoline and natural-gas engine cooling systems where a conventional fully formulated SCA coolant is specified.
Key Benefits
- Ready-to-use 50/50 prediluted coolant
- Ethylene glycol-based formulation
- Precharged with Supplemental Coolant Additives
- No SCA required at initial fill
- No water required before use
- Low-silicate formulation
- Phosphate-free
- Contains nitrite for wet-sleeve liner cavitation protection
- Helps protect cooling-system metals against corrosion
- Helps reduce the risk of scale formation
- Designed for heavy-duty diesel engines
- Suitable for gasoline and natural-gas engine cooling systems
- Helps reduce SCA mixing errors during initial fill
- Freeze protection to -34°F
- Boilover protection to 265°F with a 15 psi pressure cap
- Meets ASTM D6210, ASTM D4985, ASTM D3306 and TMC RP 329
What Does SCA Precharged Mean?
SCA stands for Supplemental Coolant Additive.
Traditional heavy-duty coolants may require a separate SCA package to establish the proper inhibitor concentration during the initial fill.
Fleet Charge is supplied with the SCA package already incorporated into the coolant.
This provides two important benefits:
- The cooling system receives the required inhibitor chemistry at initial fill
- The risk of adding too much or too little SCA during the initial fill is reduced
Fleet Charge does not require additional SCA when initially installed at the proper concentration.
The SCA level still needs to be maintained over time according to the engine, cooling-system and coolant-maintenance requirements.
Wet-Sleeve Liner Cavitation Protection
Wet-sleeve diesel engines can experience cavitation erosion around the outside surface of the cylinder liner.
Rapid pressure changes can form and collapse vapor bubbles against the liner surface. Over time, repeated bubble collapse can contribute to pitting of the metal.
Fleet Charge contains nitrite as part of its inhibitor system to help protect wet-sleeve cylinder liners against cavitation.
This makes the coolant particularly relevant for heavy-duty diesel engines that require a nitrited SCA coolant.
Heavy-Duty Diesel Applications
Fleet Charge is formulated for heavy-duty cooling systems and can be used in compatible:
- On-highway trucks
- Off-highway equipment
- Construction equipment
- Agricultural equipment
- Fleet vehicles
- Diesel-powered equipment
- Gasoline engines
- Natural-gas engines
Always verify the coolant chemistry and specification required by the engine or equipment manufacturer before filling the system.
Freeze and Boilover Protection
Fleet Charge 50/50 is already mixed to a 50% coolant and 50% water concentration.
At this concentration, the current Product Data Sheet lists:
- Freeze protection: -34°F (-37°C)
- Boilover protection: 265°F (129°C) with a 15 psi pressure cap
The published boilover value assumes sea-level atmospheric pressure and a properly functioning 15 psi cooling-system pressure cap.
Ready to Use: Do Not Add Water
Fleet Charge SCA 50/50 is a prediluted coolant.
It is already blended to the intended 50/50 concentration and should be poured directly into a compatible cooling system.
Do not add water to this 50/50 prediluted product.
Adding water changes the coolant concentration and can reduce:
- Freeze protection
- Boilover protection
- Corrosion protection
- SCA concentration
If a system requires a different coolant-to-water concentration, use the appropriate concentrate product and follow the engine manufacturer's recommendations.
Corrosion Protection
Cooling systems contain several different metals and materials that can be exposed to heat, coolant flow and electrochemical activity.
Fleet Charge is formulated to help protect cooling-system metals and components against corrosion.
Its low-silicate inhibitor package provides heavy-duty protection while the phosphate-free formulation helps reduce the potential for scale formation.
Low-Silicate, Phosphate-Free Formulation
Fleet Charge uses a low-silicate, phosphate-free coolant chemistry.
Silicate provides useful corrosion protection, but excessive levels can contribute to deposits or abrasive solids.
The phosphate-free chemistry also helps reduce the potential for scale associated with phosphate-containing coolant systems.
Coolant Maintenance
Fleet Charge is designed to simplify the initial fill because the SCA package is already present.
That does not eliminate the need for coolant maintenance.
Heavy-duty cooling systems should still be monitored for:
- Coolant concentration
- Freeze protection
- SCA or inhibitor level
- Coolant level
- Contamination
- pH and overall coolant condition
- Cooling-system leaks
Follow the engine manufacturer, cooling-system manufacturer and Fleet Charge maintenance recommendations for the specific equipment.
Compatibility With Other Coolants
Old World Industries identifies Fleet Charge as compatible with coolants meeting ASTM D6210, TMC RP 329 and compatible automotive or heavy-duty engine manufacturer specifications.
For best performance, maintaining one coolant chemistry throughout the system is preferable.
Mixing different coolant technologies can dilute the original inhibitor package or change maintenance requirements.
Specifications and Recommended Use
Meets or exceeds:
- ASTM D6210
- ASTM D4985
- ASTM D3306
- TMC RP 329
Recommended for use where the following equipment manufacturers or requirements are cited:
- Caterpillar
- GCA A-A-52624
- CNH EG-3, EG-4
- Cummins 90T8-4, CES 14603
- Detroit Fluid Specification 7SE298, 93K217
- Ford
- Freightliner 48-22880
- GM
- International
- John Deere H24, JDS-G135
- Komatsu
- Kubota
- MTU MTL 5048
- Volvo/Mack
- Waukesha
These are manufacturer recommendations and performance references, not a blanket statement of OEM approval for every engine or model.
Typical Technical Properties
| Property | Typical Value |
|---|---|
| Formulation | 50/50 Prediluted |
| Base | Ethylene Glycol |
| Color | Fuchsia |
| Specific Gravity | 1.072 |
| Boiling Point, Unpressurized | 229°F (109°C) |
| Freeze Protection | -34°F (-37°C) |
| Boilover Protection, 15 psi Cap | 265°F (129°C) |
| pH, 50 vol % | 10 minimum |
| Total Water | 50 mass % |
| Ash Content | <1 mass % |
| Chloride | <25 ppm |
| Shelf Life, Unopened Container | 5 years |
Typical properties are provided for reference and should not be treated as guaranteed batch specifications.
Frequently Asked Questions
What is Fleet Charge SCA 50/50 coolant?
Fleet Charge SCA 50/50 is a ready-to-use heavy-duty ethylene glycol antifreeze and coolant precharged with Supplemental Coolant Additives for corrosion and wet-sleeve liner cavitation protection.
Is Fleet Charge 50/50 ready to use?
Yes. The 50/50 version is already prediluted with water and is designed to be poured directly into a compatible cooling system.
Do I add water to Fleet Charge 50/50?
No. Fleet Charge 50/50 is already diluted to its intended concentration. Adding water will change its freeze, boilover and inhibitor protection.
Does Fleet Charge contain SCA?
Yes. Fleet Charge is precharged with Supplemental Coolant Additives.
Do I need to add SCA when first filling the system?
No. Additional SCA is not required at the initial fill because Fleet Charge already contains the SCA package.
Does Fleet Charge require SCA maintenance later?
Yes. The initial SCA charge does not make the coolant maintenance-free. Inhibitor concentration should be maintained according to Fleet Charge and equipment manufacturer recommendations.
Is Fleet Charge a heavy-duty diesel coolant?
Yes. Fleet Charge is specifically formulated as a fully formulated heavy-duty coolant and is suitable for compatible diesel cooling systems.
Can Fleet Charge be used in wet-sleeve diesel engines?
Yes. The coolant contains nitrite to help protect wet-sleeve cylinder liners against cavitation erosion.
What is coolant cavitation?
Cavitation occurs when vapor bubbles form and rapidly collapse against metal surfaces. In wet-sleeve diesel engines, repeated cavitation can cause pitting on cylinder liners. Fleet Charge includes nitrite-based protection to help control this type of damage.
What temperature does Fleet Charge 50/50 protect against?
The 50/50 prediluted formulation provides freeze protection to approximately -34°F (-37°C).
What is the boilover protection of Fleet Charge 50/50?
The Product Data Sheet lists boilover protection to approximately 265°F (129°C) when used with a 15 psi pressure cap at sea level.
Is Fleet Charge phosphate-free?
Yes. Fleet Charge uses a phosphate-free formulation.
Is Fleet Charge low silicate?
Yes. The product is formulated as a low-silicate heavy-duty coolant.
What color is Fleet Charge coolant?
Fleet Charge is fuchsia, commonly described as a pink coolant.
Does Fleet Charge meet ASTM D6210?
Yes. Fleet Charge meets or exceeds ASTM D6210.
Does Fleet Charge meet ASTM D3306?
Yes. Fleet Charge meets or exceeds ASTM D3306.
Does Fleet Charge meet ASTM D4985?
Yes. Fleet Charge meets or exceeds ASTM D4985.
Does Fleet Charge meet TMC RP 329?
Yes. TMC RP 329 is listed among the current performance requirements.
Can Fleet Charge be used in gasoline engines?
Yes. Fleet Charge is designed for compatible diesel, gasoline and natural-gas engine cooling systems.
Can Fleet Charge be mixed with other coolants?
Old World Industries identifies Fleet Charge as compatible with coolants that meet ASTM D6210, TMC RP 329 and compatible automotive or heavy-duty OEM specifications. For best performance and simpler maintenance, maintaining one coolant chemistry is preferable.
What is the difference between Fleet Charge and Final Charge?
Fleet Charge is a conventional fully formulated SCA-precharged coolant containing nitrite and requiring ongoing inhibitor maintenance. Final Charge Global is an extended-life OAT coolant that does not use conventional supplemental coolant additives. The correct choice depends on the coolant chemistry and specification required by the engine manufacturer.
How long can unopened Fleet Charge 50/50 be stored?
The current Product Data Sheet lists a shelf life of 5 years for the unopened 50/50 prediluted product when stored appropriately.
There aren't any reviews yet. Write a Review.

Product Videos